10HP past muhit haroratidagi issiqlik pompasi

Qisqa Tasvir:

SolarShine 10HP past muhit haroratidagi issiqlik pompasieganing afzalligisuv va elektr energiyasini ajratish, chiqindi gaz yo'q,no chiqindi qoldiqlari, xavfsiz va ishonchli, yuqori samaradorlik, energiya tejash va yashil atrof-muhit muhofazasi.Past atrof-muhit haroratida ishlashni davom eting -25


Mahsulot detali

Mahsulot teglari

Past haroratli issiqlik nasosining tavsifi

Turi

Past atrof-muhit harorati havo manbali issiqlik pompasi

Uy-joy materiali

Plastik, galvanizli qatlam

Saqlash / Tanksiz

Sirkulyatsiya isitish

O'rnatish

Mustaqil, devorga o'rnatiladigan / mustaqil

Foydalanish

Issiq suv / polni isitish / fankoil isitish va sovutish

Isitish quvvati

4,5-20 kVt

Sovutgich

R410a/ R417a/ R407c/ R22/ R134a

Kompressor

Copeland, Copeland Scroll kompressori

Kuchlanishi

220V 〜l o'tkazgich, 3800VAC/50Hz

Quvvatlantirish manbai

50/60 Gts

Funktsiya

Uyni isitish, xonani isitish va issiq suv, hovuz suvini isitish, sovutish va issiq suv

Politsiya

4.10-4.13

Issiqlik almashtirgich

Shell issiqlik almashinuvchisi

Evaporatator

Oltin gidrofil alyuminiy fin

Ishlayotgan muhit harorati

Minus -25-45 daraja

Kompressor turi

Copeland Scroll kompressori

Rang

Oq, Kulrang

Ilova

Jakuzi Spa / Hovuz, Mehmonxona, Savdo va Sanoat

Kirish quvvati

2,8-30 kVt

Yuqori yorug'lik

sovuq haroratli issiqlik pompasi, inverter havo manbali issiqlik pompasi

Past haroratli havo manbali issiqlik nasosining ishlash printsipi qanday?

Issiqlik nasosi moslamasi evaporatator, kondensator, kompressor va kengaytirish klapanidan iborat yopiq tizim bo'lib, u tegishli miqdorda sovutgich bilan to'ldiriladi.

Issiqlik pompasi ishlashining asosiy printsipi teskari Karno aylanishi printsipiga asoslanadi: suyuq sovutgich birinchi navbatda evaporatatordagi havodagi issiqlikni o'zlashtiradi va bug' hosil qilish uchun bug'lanadi (bug'lanish), bug'lanishning yashirin issiqligi esa qayta tiklangan issiqlikdir.Keyin u kompressor tomonidan yuqori haroratli va yuqori bosimli gazga siqiladi va so'rilgan issiqlikni kerakli isitiladigan hovuz suviga yuborish uchun suyuqlikka (suyultirish) kondensatsiyalanish uchun kondensatorga kiradi, Suyuq sovutgich bosimni yo'qotgandan keyin kengaytirish valfiga qaytadi va kengaytirish valfi orqali kengayish, issiqlikni yutadi va tsiklni yakunlash uchun bug'lanadi.Shu tarzda, u doimiy ravishda past haroratli manbaning issiqligini o'zlashtiradi va oldindan belgilangan haroratga to'g'ridan-to'g'ri erishish uchun isitiladigan suzish havzasi suvini chiqaradi.

past haroratli issiqlik nasosining spetsifikatsiyasi

Model

KDR-03

KDR-05S

KDR-05-G

KDR-07-G

KDR-10-G

KDR-15

KDR-20

KDR-25

HP

3 HP

5 HP

5 HP

7 ot kuchi

10 ot kuchi

15 ot kuchi

20 ot kuchi

25 ot kuchi

Quvvatlantirish manbai

220V/380V

220V

380V

380V

380V

380V

380V

380V

Kirish quvvati

2.8

4.2

4.7

5.2

9.2

13

18.5

20.5

Har xil muhitda isitish quvvati chiqishi.

(20℃)

10.8

16.2

18

20

35.4

50

71.2

78.9

(6/7℃)

9

13.7

15.3

16.9

30

42.3

60

66.6

(-6/7℃)

6.9

10.3

11.5

12.7

22.5

319

453

50.2

(-15℃)

5.9

8.8

9.9

10.9

19.3

273

38.9

43

(-20℃)

5.2

7.8

8.7

9.6

17

24

34.2

37.9

Sovutish quvvati chiqishi

8.0

12.0

13.4

14.8

26.2

37.1

52.7

68.4

Fan chiqishi yo'nalishi

Yon

Yon

Yon

Yon

Yon

Yon

Yuqori

Yuqori

V\faler ulanish

DN25

ON25

DN25

DN25

DN32

DN40

DN50

DN50

Suyuqlik tezligi (M3/H)

2-3

4-5

5-6

5-7

7-10

12-15

15-20

20-25

O'lchov

(MM)

1152

1190

1190

1190

1350

1350

1800

1800

(MM)

422

425

425

425

645

645

1100

1100

(MM)

768

1240

1240

1240

1845 yil

184S

2100

2100

Og'irligi (kg)

130

180

160

220

310

355

630

780

Oddiy issiqlik nasoslari bilan solishtirganda - 10 ℃ va undan past haroratlarda bug'lanish harorati juda past bo'lib, bug'lanish kamroq bo'ladi, natijada kompressorning qaytib keladigan havo hajmi kamroq bo'ladi, bu kondensatsiya va issiqlik chiqishiga ta'sir qiladi.Kompressorni bog'laydigan in'ektsiya entalpiyasini ko'paytiruvchi tarmoq ultra past atrof-muhit haroratidagi issiqlik pompasiga qo'shiladi.Kompressorning qaytib keladigan havosi etarli bo'lmaganda, in'ektsiya entalpiyasini ko'paytiruvchi filial kompressor uchun havo hosil qiladi, shuning uchun kondensatorning issiqlik chiqishi ortadi, shuning uchun u hali ham juda past haroratda normal issiqlik ishlab chiqarishi mumkin.

Qo'llash holatlari


  • Oldingi:
  • Keyingisi: