Turi | Past atrof-muhit harorati havo manbali issiqlik pompasi | Uy-joy Material | Plastik, galvanizli qatlam |
Saqlash / Tanksiz | Sirkulyatsiya isitish | O'rnatish | Mustaqil, devorga o'rnatilgan / Mustaqil |
Foydalanish | Issiq suv / polni isitish / fankoil isitish va sovutish | Isitish Imkoniyat | 4,5-20 kVt |
Sovutgich | R410a/ R417a/ R407c/ R22/ R134a | Kompressor | Copeland, Copeland Scroll kompressori |
Kuchlanishi | 220V〜lnverter,3800VAC/50Hz | Quvvat Ta'minot | 50/60 Gts |
Funktsiya | Uyni isitish, xonani isitish va issiq suv, hovuz suvini isitish, sovutish va issiq suv | Politsiya | 4.10-4.13 |
Issiqlik almashtirgich | Shell issiqlik almashinuvchisi | Evaporatator | Oltin gidrofil alyuminiy fin |
Ishlash Atrof muhit Harorat | Minus -25-45 daraja | Kompressor Turi | Copeland Scroll kompressori |
Rang | Oq, Kulrang | Ilova | Jakuzi Spa / Hovuz, Mehmonxona, Savdo va Sanoat |
Kirish quvvati | 2,8-30 kVt | Yuqori yorug'lik | sovuq haroratli issiqlik pompasi, inverter havo manbali issiqlik pompasi |
Atrof-muhitning har xil haroratlari issiqlik pompasi qurilmasining xizmat ko'rsatish effektiga va xizmat muddatiga ta'sir qiladi.Shimoldagi past atrof-muhit harorati ostida, issiqlik nasoslarining normal ishga tushishi va ishlashini ta'minlash uchun past haroratli harorat uchun maxsus ultra past haroratli issiqlik nasosidan foydalanish kerak. issiqlik pompasi kompressori, u ham barqaror ishlaydi, samarali isitadi va ultra past haroratli muhit sharoitida -25 ℃ ga qadar jihozning xizmat qilish muddatini uzaytiradi.
Model | KDR-03 | KDR-05S | KDR-05-G | KDR-07-G | KDR-10-G | KDR-15 | KDR-20 | KDR-25 | |
HP | 3 HP | 5 HP | 5 HP | 7 ot kuchi | 10 ot kuchi | 15 ot kuchi | 20 ot kuchi | 25 ot kuchi | |
Quvvatlantirish manbai | 220V/380V | 220V | 380V | 380V | 380V | 380V | 380V | 380V | |
Kirish quvvati | 2.8 | 4.2 | 4.7 | 5.2 | 9.2 | 13 | 18.5 | 20.5 | |
Har xil muhitda isitish quvvati chiqishi. | (20℃) | 10.8 | 16.2 | 18 | 20 | 35.4 | 50 | 71.2 | 78.9 |
(6/7℃) | 9 | 13.7 | 15.3 | 16.9 | 30 | 42.3 | 60 | 66.6 | |
(-6/7℃) | 6.9 | 10.3 | 11.5 | 12.7 | 22.5 | 319 | 453 | 50.2 | |
(-15℃) | 5.9 | 8.8 | 9.9 | 10.9 | 19.3 | 273 | 38.9 | 43 | |
(-20℃) | 5.2 | 7.8 | 8.7 | 9.6 | 17 | 24 | 34.2 | 37.9 | |
Sovutish quvvati chiqishi | 8.0 | 12.0 | 13.4 | 14.8 | 26.2 | 37.1 | 52.7 | 68.4 | |
Fan chiqishi yo'nalishi | Yon | Yon | Yon | Yon | Yon | Yon | Yuqori | Yuqori | |
V\faler ulanish | DN25 | ON25 | DN25 | DN25 | DN32 | DN40 | DN50 | DN50 | |
Suyuqlik tezligi (M3/H) | 2-3 | 4-5 | 5-6 | 5-7 | 7-10 | 12-15 | 15-20 | 20-25 | |
O'lchov | (MM) | 1152 | 1190 | 1190 | 1190 | 1350 | 1350 | 1800 | 1800 |
(MM) | 422 | 425 | 425 | 425 | 645 | 645 | 1100 | 1100 | |
(MM) | 768 | 1240 | 1240 | 1240 | 1845 yil | 184S | 2100 | 2100 | |
Og'irligi (kg) | 130 | 180 | 160 | 220 | 310 | 355 | 630 | 780 |
Nima uchun havo manbali issiqlik pompasi barqaror ishlashi mumkin - 25℃?
Ko'pchilikning havo manbali issiqlik nasosini noto'g'ri tushunishi asosan past atrof-muhit haroratida barqaror ishlay oladimi yoki yo'qmi degan savolga qaratilgan.,asosan, ular hali ham oddiy issiqlik nasoslari haqidagi oldingi tushunchalarida qolishganligi va past haroratli issiqlik nasoslari haqida etarli tushunchaga ega emasligi.
Past haroratli issiqlik pompasi va oddiy issiqlik pompasi o'rtasidagi ishlash farqini keltirib chiqaradigan asosiy komponent kompressordir.Past haroratli issiqlik nasosining atrof-muhitning past haroratida normal ishlashining sababi an'anaviy issiqlik pompasi duch keladigan bir nechta muammolarni hal qilishdir - isitish quvvati etarli emas, past bosim va past bug'lanish harorati, past assimilyatsiya oqimi, katta siqish nisbati tufayli beqaror ishlash. va yuqori egzoz harorati.
Birinchisi, ichki tuzilmaning dizayni.Past haroratli issiqlik pompasi kompressorining aylantirish profiliiskattaroq ishlab chiqilgan, ya'ni pastroq bug'lanish harorati sharoitida past haroratli issiqlik pompasi yuqori ish samaradorligi va past haroratli harorat farqi bo'lgan ish muhitiga moslashish uchun past haroratli issiqlik nasosini olishi mumkin.