Sovuq hududlar uchun 3HP past muhit harorati issiqlik pompasi

Qisqa Tasvir:

3HP past haroratli havo manbali issiqlik pompasi sovuq iqlimli hududlar uchun mos bo'lgan -25 ℃ past haroratli muhitda normal ishlashi mumkin.
Past haroratli havo manbali issiqlik nasosining issiq havo fanati katta assimilyatsiya quvvati va sezilarli muzdan tushirish qobiliyatiga ega bo'lgan ikki bosqichli kompressorni qabul qiladi, shuning uchun u past haroratli muhitda normal ishlashni ta'minlaydi va havoni isitish, erdan isitish va issiq suv bilan ta'minlaydi. past haroratli hududlar.


Mahsulot detali

Mahsulot teglari

Past haroratli issiqlik nasosining tavsifi

Turi

Past atrof-muhit harorati havo manbali issiqlik pompasi

Uy-joy Material

Plastik, galvanizli qatlam

Saqlash / Tanksiz

Sirkulyatsiya isitish

O'rnatish

Mustaqil, devorga o'rnatilgan / Mustaqil

Foydalanish

Issiq suv / polni isitish / fankoil isitish va sovutish

Isitish Imkoniyat

4,5-20 kVt

Sovutgich

R410a/ R417a/ R407c/ R22/ R134a

Kompressor

Copeland, Copeland Scroll kompressori

Kuchlanishi

220Vlnverter,3800VAC/50Hz

Quvvat Ta'minot

50/60 Gts

Funktsiya

Uyni isitish, xonani isitish va issiq suv, hovuz suvini isitish, sovutish va issiq suv

Politsiya

4.10-4.13

Issiqlik almashtirgich

Shell issiqlik almashinuvchisi

Evaporatator

Oltin gidrofil alyuminiy fin

Ishlash Atrof muhit Harorat

Minus -25-45 daraja

Kompressor Turi

Copeland Scroll kompressori

Rang

Oq, Kulrang

Ilova

Jakuzi Spa / Hovuz, Mehmonxona, Savdo va Sanoat

Kirish quvvati

2,8-30 kVt

Yuqori yorug'lik

sovuq haroratli issiqlik pompasi, inverter havo manbali issiqlik pompasi

Atrof-muhitning har xil haroratlari issiqlik pompasi qurilmasining xizmat ko'rsatish effektiga va xizmat muddatiga ta'sir qiladi.Shimoldagi past atrof-muhit harorati ostida, issiqlik nasoslarining normal ishga tushishi va ishlashini ta'minlash uchun past haroratli harorat uchun maxsus ultra past haroratli issiqlik nasosidan foydalanish kerak. issiqlik pompasi kompressori, u ham barqaror ishlaydi, samarali isitadi va ultra past haroratli muhit sharoitida -25 ℃ ga qadar jihozning xizmat qilish muddatini uzaytiradi.

past haroratli issiqlik nasosining spetsifikatsiyasi

Model

KDR-03

KDR-05S

KDR-05-G

KDR-07-G

KDR-10-G

KDR-15

KDR-20

KDR-25

HP

3 HP

5 HP

5 HP

7 ot kuchi

10 ot kuchi

15 ot kuchi

20 ot kuchi

25 ot kuchi

Quvvatlantirish manbai

220V/380V

220V

380V

380V

380V

380V

380V

380V

Kirish quvvati

2.8

4.2

4.7

5.2

9.2

13

18.5

20.5

Har xil muhitda isitish quvvati chiqishi.

(20℃)

10.8

16.2

18

20

35.4

50

71.2

78.9

(6/7℃)

9

13.7

15.3

16.9

30

42.3

60

66.6

(-6/7℃)

6.9

10.3

11.5

12.7

22.5

319

453

50.2

(-15℃)

5.9

8.8

9.9

10.9

19.3

273

38.9

43

(-20℃)

5.2

7.8

8.7

9.6

17

24

34.2

37.9

Sovutish quvvati chiqishi

8.0

12.0

13.4

14.8

26.2

37.1

52.7

68.4

Fan chiqishi yo'nalishi

Yon

Yon

Yon

Yon

Yon

Yon

Yuqori

Yuqori

V\faler ulanish

DN25

ON25

DN25

DN25

DN32

DN40

DN50

DN50

Suyuqlik tezligi (M3/H)

2-3

4-5

5-6

5-7

7-10

12-15

15-20

20-25

O'lchov

(MM)

1152

1190

1190

1190

1350

1350

1800

1800

(MM)

422

425

425

425

645

645

1100

1100

(MM)

768

1240

1240

1240

1845 yil

184S

2100

2100

Og'irligi (kg)

130

180

160

220

310

355

630

780

Nima uchun havo manbali issiqlik pompasi barqaror ishlashi mumkin - 25?

Ko'pchilikning havo manbali issiqlik nasosini noto'g'ri tushunishi asosan past atrof-muhit haroratida barqaror ishlay oladimi yoki yo'qmi degan savolga qaratilgan.,asosan, ular hali ham oddiy issiqlik nasoslari haqidagi oldingi tushunchalarida qolishganligi va past haroratli issiqlik nasoslari haqida etarli tushunchaga ega emasligi.

Past haroratli issiqlik pompasi va oddiy issiqlik pompasi o'rtasidagi ishlash farqini keltirib chiqaradigan asosiy komponent kompressordir.Past haroratli issiqlik nasosining atrof-muhitning past haroratida normal ishlashining sababi an'anaviy issiqlik pompasi duch keladigan bir nechta muammolarni hal qilishdir - isitish quvvati etarli emas, past bosim va past bug'lanish harorati, past assimilyatsiya oqimi, katta siqish nisbati tufayli beqaror ishlash. va yuqori egzoz harorati.

Birinchisi, ichki tuzilmaning dizayni.Past haroratli issiqlik pompasi kompressorining aylantirish profiliiskattaroq ishlab chiqilgan, ya'ni pastroq bug'lanish harorati sharoitida past haroratli issiqlik pompasi yuqori ish samaradorligi va past haroratli harorat farqi bo'lgan ish muhitiga moslashish uchun past haroratli issiqlik nasosini olishi mumkin.

Qo'llash holatlari


  • Oldingi:
  • Keyingisi: